Insertion flowmeter or batch controller with paddle wheel and flow transmitter or remote batch controller
Type 8025 / Article No. 418424
Product description
The Type 8025 flowmeter or batch controller is specially designed for use in neutral, slightly aggressive, solid-free liquids. Type 8025 flowmeter is offered in different versions. • The compact flowmeter with paddle wheel sensor is available in two versions: – standard signal output or – battery powered indicator/totalizer version without output. • The remote transmitter is available in two versions: – Universal transmitter for control cabinet or wall mounting, which can be connected to other flow sensors; sensors with open collector output, reed relay output, TTL, CMOS or coil can be operated by this transmitter. – Transmitter, for control cabinet or wall mounting: standard signal input for combination with the Bürkert Type 8020/8030/SE30+S077 flowmeters “Low Power” version. Type 8025 batch controller is also available in various versions: • The compact batch controller with paddle wheel sensor • The remote batch controller for control cabinet or wall mounting for coupling to the Bürkert Type 8020/8030/8031/8041/SE30+S077 flowmeters or to other flow sensors; sensors with open collector output, reed relay output, TTL, CMOS or coil can be operated by this batch controller.
- Commodity Codes
- 90261021
- Country
- FR
Technical attributes
Name |
Value |
Unit |
---|---|---|
Type | 8025 | |
Product sub-group | Flow rate | |
Flow rate (volume) | Yes | |
Concentration 1 | No | |
Continuous measurement | Yes | |
Dosing | No | |
Switch | No | |
Construction device | Compact | |
Display type | Display | |
Protection class measurement device (IP) | IP65 | |
AC Voltage min. | 115 | V |
AC Voltage max. | 230 | V |
Voltage frequency | 50/60 | Hz |
Battery voltage | No | |
Precision of volume flow rate in relation to reading | 1 | % |
Temperature environment min | -10 | °C |
Temperature environment max | 50 | °C |
Temperature medium min | -15 | °C |
Temperature medium max | 80 | °C |
Nominal pressure (DIN EN 1333) | PN 10 | |
Dynamic viscosity min. | 0 | cP |
Dynamic viscosity max. | 300 | cP |
Detection of flow direction | No | |
Transmitter type | Basic | |
Sensor type | Paddle wheel | |
Paddle wheel type | Magnetic | |
Paddle wheel measuring principle detection | Hall | |
Fitting electronic interface | Insertion 2 (inch) | |
Electrical connection 1 type | Cable gland M20 | |
Electrical connection 1 quantity | 2 | PCE |
Electrical connection 1 gender | Terminal block | |
Electrical connection 1 material category | Plastics | |
Electrical connection 1 material | PA (Polyamide) | |
Electrical connection seal 1 material | Neoprene | |
Output type analog quantity | 1 | PCE |
Output 1 type analog current | 4-20 mA | |
Output 1 digital type | Transistor | |
Output 1 digital transistor connection NPN | Yes | |
Output 1 digital transistor connection PNP | Yes | |
Digital output 1 transistor contactless | 0,1 | A |
Electronics body material category | Plastics | |
Electronics body material | PC (Polycarbonate) | |
Cover material | PC (polycarbonate) | |
Protective cover material | PC (polycarbonate) | |
Nut material | PC (polycarbonate) | |
Front foil material category | Plastics | |
Front foil material | Polyester | |
Sensor/housing seal material | FKM (fluororubber) | |
Seal housing/cover material | NBR | |
Protective cover seal material | Silicone | |
Screws material | Stainless steel | |
Attachment part material | PSU (polysulfone)/PPSU (polyphenylsulfone) | |
Parametrisation local | Yes | |
Parametrisation separate | No | |
Parametrisation fixed | No | |
sensor holder material composition | Plastics | |
Sensor holder material | PVDF (Polyvinylidene fluoride) | |
Medium-contacting parts seal material | FKM (Fluor rubber) | |
Paddle wheel material | PVDF (Polyvinylidene fluoride) | |
Paddle wheel axle material | Ceramic | |
Bearing material category | Technical ceramics | |
Bearing material | Ceramic | |
Insertion sensor length | long | |
Tropical climate version | Yes | |
Time dosing | No | |
Batch dosing | No | |
Extended diagnosis | No | |
Volumeter | Yes | |
Weight | 1 | kg |